"Three suture materials were used: Ethibond, Fiberwire, and Nespron. They were tied with either the antislip knot using a pair of United States Pharmacopeia (USP) 2 sutures or with a conventional reef knot using USP2 single sutures. The volume and tensile strength of the knots were measured (n = 25 for each combination of suture and method). The maximum tensile strength was observed with Fiberwire antislip knots with five throws (mean 587 N) and six throws (mean 590 N),...